TaKaRa
Á¦Ç°¸í/Á¦Ç°ÄÚµå
Å°¿öµå°Ë»ö
°Ë»ö
Portable Single tube Luminometer

Lucetta¢â 2 Luminometer

-

Á¦Á¶»ç Á¦Ç°ÄÚµå Á¦Ç°¸í ¿ë·® °¡°Ý
(ºÎ°¡¼¼º°µµ)
ºñ°í »ç¿ëÀڸŴº¾ó
Lonza
AAL-1002
Lucetta¢â 2 Luminometer
°ü·ÃÇмú ±¸¸ÅÇϱ⠵¥¸ð½Åû 
1 ´ë
°¡°Ý¹®ÀÇ   main body Lucetta2 Manual.pdf
Lonza
SAAF-1003
Lucetta¢â 2 Connect
°ü·ÃÇмú ±¸¸ÅÇϱâ
1 ea
°¡°Ý¹®ÀÇ   PC connection SW Lucetta2 Manual.pdf

Á¦Ç°¼³¸í
Lucetta 2 Luminometer´Â bioluminescence¿Í chemiluminescence°ËÃâÀ» À§ÇØ °³¹ßµÈ single tube ŸÀÔÀÇ luminometerÀÌ´Ù. ¿ÜºÎ Àü¿øÀ¸·Î ÀÛµ¿ÇÒ »Ó¸¸ ¾Æ´Ï¶ó È޴뼺°ú À̵¿¼ºÀ» À§ÇØ battery¿¡ ÀÇÇÑ ÀÛµ¿µµ °¡´ÉÇÏ¿© Àå¼Ò¿¡ ±¸¾Ö¹ÞÁö ¾Ê°í »ç¿ëÀÌ °¡´ÉÇϸç, ¸ðµç luminescence °ËÃâ¿¡ ÀÌ¿ëÀÌ °¡´ÉÇÑ LuminometerÀÌ´Ù.
º» Àåºñ´Â Ultra fast single photon counter¸¦ detector·Î ä¿ëÇÏ¿´°í, ³»/¿ÜºÎ·ÎºÎÅÍÀÇ light ³ëÃâÀ» È¿°úÀûÀ¸·Î Â÷´ÜÇÒ ¼ö ÀÖµµ·Ï ¼³°èµÈ chamber¸¦ žÀçÇÏ¿© 1 fmol ¼öÁØÀÇ ATP±îÁöµµ °ËÃâ °¡´ÉÇÑ ³ôÀº ¹Î°¨µµ¸¦ ³ªÅ¸³½´Ù.
ƯÈ÷ luminescence¸¦ ÀÌ¿ëÇÏ¿© ½Å¼ÓÇÏ°Ô Mycoplasma °ËÃâÇÒ ¼ö ÀÖ´Â MycoAlert kit(LonzaÞä) Á¦Ç°¿¡ ÃÖÀûÈ­µÈ SW¸¦ ±âº»À¸·Î žÀçÇÏ°í ÀÖ¾î, ÇØ´ç Á¦Ç°À» ÀÌ¿ëÇÑ Mycoplasma detection assay½Ã ÃøÁ¤ Áï½Ã ÇØ´ç »ùÇÃÀÇ Mycoplasma °¨¿°¿©ºÎ(Clear, Border line, Contaminated)¿¡ ´ëÇÑ °á°ú¸¦ °è»ê, Á¦°øÇØ ÁØ´Ù.
¶ÇÇÑ Lucetta 2 Luminometer´Â Single read mode¸¦ ÀÌ¿ëÇÏ¿© cell proliferation, cytotoxicity ÃøÁ¤ ¶Ç´Â luciferase reporter gene assays¿Í °°Àº luminescence-based assay¿¡ ÀûÇÕÇÑ Á¦Ç°ÀÌ´Ù.


[MycoAlert Plus Mycoplasma Detection Kit¿Í À̸¦ ÀÌ¿ëÇÑ Mycoplasma °ËÃâ work flow]

Á¦Ç°Æ¯Â¡
- Small, portable tube luminometer
- Stand-alone instrument without PC requirements
- High sensitivity and linearity
- Specific measurement mode for running MycoAlertTM Mycoplasma Detection Assays
- Quick single read mode for unprocessed luminescence readings
- High data storage capacity with maximum storage of up to 2,000 single sample readings
ÀÀ¿ëºÐ¾ß(application)
- MycoAlert Mycoplasma Detection Assays
- ATP assays (ViaLight Cell Proliferation and Cytotoxicity Assay
- Adenylate Kinase assays (ToxiLight Non-destructive Cytotoxicity Assay)
- Luciferase reporter gene analysis (Beetle Juice/ Renilla / Gaussia-Juice)
Technical specifications

Detector

Ultra fast single photon counter with spectral sensitivity range of 380-630nm

Sensitivity

1 fmol ATP using the ATP Bioluminescence Assay Kit CLSII(Boehringer Mannheim, FRG)

Background Value

Background average < 20 RLU/s

Interfaces

Graphic display with backlit LED, 128 x 64 dots

Data storage

Storage of the last 2000 results

PC-software

Data capture software program Lucetta¢â Connect for data transfer to Excel¢ç

Dimensions(w x d x h)

150mm x 280mm x 170mm

Weight

Approx. 2 kg (4.4 lbs), incl. batteries

Power supply

Universal input : 100-240V AC, 50-60Hz

Batteries

3 rechageable Ni/MH akku Baby, 1.2V / 4000mAh


Keyword :

Lucetta 2 Luminometer
>
Portable Single tube Luminometer
Lucetta¢â 2 Luminometer